{"id":1707,"date":"2026-07-26T14:26:53","date_gmt":"2026-07-26T14:26:53","guid":{"rendered":"https:\/\/geec.vn\/?p=1707"},"modified":"2026-07-26T16:35:18","modified_gmt":"2026-07-26T16:35:18","slug":"bms-la-gi-pham-vi-dung-va-11-hang-muc-toi-thieu-can-co","status":"publish","type":"post","link":"https:\/\/geec.vn\/en\/bms-la-gi-pham-vi-dung-va-11-hang-muc-toi-thieu-can-co\/","title":{"rendered":"What is BMS? The Right Scope and 11 Minimum Required Items"},"content":{"rendered":"<p class=\"wp-block-paragraph\">In many current projects, the phrase <strong>BMS (Building Management System)<\/strong> It is often used as an \"all-inclusive\" solution. However, in reality, many projects have invested billions of VND in BMS but still have to use various other software programs to operate after handover.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The cause is not technology.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The reason lies in the fact that <strong>x\u00e1c \u0111\u1ecbnh sai ph\u1ea1m vi BMS ngay t\u1eeb giai \u0111o\u1ea1n thi\u1ebft k\u1ebf v\u00e0 \u0111\u1ea7u t\u01b0<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This article will help investors, building management, facility managers, and technical teams understand correctly:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>What is BMS?<\/li>\n\n\n\n<li>What does BMS actually do?<\/li>\n\n\n\n<li>Which systems need integration?<\/li>\n\n\n\n<li>Which systems are not within the scope of BMS?<\/li>\n\n\n\n<li>11 minimum required items<\/li>\n\n\n\n<li>How to assess whether a BMS system is functioning correctly.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h1 class=\"wp-block-heading\">What is BMS?<\/h1>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>BMS (Building Management System)<\/strong> It is a system for centrally managing and controlling mechanical and electrical (M&amp;E) systems in a building in real time.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Unlike platforms that only display data, BMS has the capability to:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2705 Data collection<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2705 Analyze device status<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2705 Automatic control<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2705 Activate the operational logic<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2705 Incident alert<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2705 Saves activity history<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In other words:<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">BMS is the operational brain of the building.<\/p>\n<\/blockquote>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h1 class=\"wp-block-heading\">The Difference Between BMS and Monitoring Systems<\/h1>\n\n\n\n<p class=\"wp-block-paragraph\">Many people confuse:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Monitoring dashboard<\/li>\n\n\n\n<li>IoT Platform<\/li>\n\n\n\n<li>Energy Monitoring<\/li>\n\n\n\n<li>BMS<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">The most important difference is:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>Function<\/th><th>Monitoring<\/th><th>BMS<\/th><\/tr><tr><td>Read data<\/td><td>\u2705<\/td><td>\u2705<\/td><\/tr><tr><td>Display Dashboard<\/td><td>\u2705<\/td><td>\u2705<\/td><\/tr><tr><td>Operational warning<\/td><td>\u2705<\/td><td>\u2705<\/td><\/tr><tr><td>Device control<\/td><td>\u274c<\/td><td>\u2705<\/td><\/tr><tr><td>Logic Automation<\/td><td>\u274c<\/td><td>\u2705<\/td><\/tr><tr><td>Sequence Management<\/td><td>\u274c<\/td><td>\u2705<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">If a system can only read data but cannot control the devices, it cannot be called a complete BMS system.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h1 class=\"wp-block-heading\">What value does BMS bring?<\/h1>\n\n\n\n<h2 class=\"wp-block-heading\">1. Operational Automation<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">BMS helps:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Automatic HVAC on\/off<\/li>\n\n\n\n<li>Adjust the temperature<\/li>\n\n\n\n<li>Adjust humidity<\/li>\n\n\n\n<li>Scheduling equipment<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Significantly reduces manual tasks for the operations team.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">2. Reduce Power Consumption<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Normally:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>HVAC accounts for 40\u201360% of a building's total electricity consumption.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">BMS helps:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Optimize cooling load<\/li>\n\n\n\n<li>Chiller control<\/li>\n\n\n\n<li>Alternate pumping<\/li>\n\n\n\n<li>Lighting control<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">This will reduce annual OPEX costs.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">3. Centralized Monitoring<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">FM can be tracked:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>HVAC<\/li>\n\n\n\n<li>Electricity<\/li>\n\n\n\n<li>Water<\/li>\n\n\n\n<li>Illumination<\/li>\n\n\n\n<li>Auxiliary systems<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">on the same platform.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">4. Enhancing Reliability<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Automatic detection system:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Power outage<\/li>\n\n\n\n<li>Overloaded<\/li>\n\n\n\n<li>Faulty device<\/li>\n\n\n\n<li>Operational warning<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">before affecting the user.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h1 class=\"wp-block-heading\">The Correct Scope of BMS<\/h1>\n\n\n\n<p class=\"wp-block-paragraph\">This is the most important part of the entire article.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h1 class=\"wp-block-heading\">The systems SHOULD be located within the BMS.<\/h1>\n\n\n\n<h2 class=\"wp-block-heading\">HVAC<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Chiller<\/li>\n\n\n\n<li>Cooling Tower<\/li>\n\n\n\n<li>AHU<\/li>\n\n\n\n<li>FCU<\/li>\n\n\n\n<li>VAV<\/li>\n\n\n\n<li>Cold water pump<\/li>\n\n\n\n<li>Condensate pump<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">This is the most important component of any BMS system.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Electricity<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The BMS should monitor:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Transformer<\/li>\n\n\n\n<li>MSB<\/li>\n\n\n\n<li>MDB<\/li>\n\n\n\n<li>ATS<\/li>\n\n\n\n<li>Generator<\/li>\n\n\n\n<li>UPS<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">And the parameters:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>kWh<\/li>\n\n\n\n<li>kW<\/li>\n\n\n\n<li>PF<\/li>\n\n\n\n<li>Voltage<\/li>\n\n\n\n<li>Current<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Water System<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Booster pump<\/li>\n\n\n\n<li>Water supply pump<\/li>\n\n\n\n<li>Drainage pump<\/li>\n\n\n\n<li>Rooftop pool<\/li>\n\n\n\n<li>Underground tank<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Common Area Lighting<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Lobby<\/li>\n\n\n\n<li>Lobby<\/li>\n\n\n\n<li>Parking lot<\/li>\n\n\n\n<li>Public area<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Scheduling theo:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Operating hours<\/li>\n\n\n\n<li>Presence sensor<\/li>\n\n\n\n<li>Holiday<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Ventilation<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Turbocharger<\/li>\n\n\n\n<li>Smoke extraction<\/li>\n\n\n\n<li>Basement ventilation<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h1 class=\"wp-block-heading\">These systems should NOT be controlled directly via the BMS.<\/h1>\n\n\n\n<h2 class=\"wp-block-heading\">Fire Alarm System<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A BMS should only:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2705 Read status<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2705 Receive alert signals<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2705 Activate HVAC interlock<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Kh\u00f4ng n\u00ean:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u274c Firefighting logic control<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u274c Replace Fire Alarm Controller<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">CCTV<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">BMS is not a system:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Camera<\/li>\n\n\n\n<li>NVR<\/li>\n\n\n\n<li>Video Analytics<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">State integration only.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Access Control<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">BMS is not a replacement for:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Door lock controller<\/li>\n\n\n\n<li>User management<\/li>\n\n\n\n<li>Access card<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">CMMS<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">BMS is not a replacement for:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Maintenance management<\/li>\n\n\n\n<li>Work Order<\/li>\n\n\n\n<li>Spare Parts<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">That is the role of CMMS.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h1 class=\"wp-block-heading\">4 Essential Items That Must Be Included<\/h1>\n\n\n\n<p class=\"wp-block-paragraph\">A proper BMS must have at least:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">1. HVAC Control<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">2. Electrical Monitoring<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">3. Lighting Scheduling<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">4. Water System Monitoring<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">If any of these four groups are missing, the operational value of the BMS will decrease significantly.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h1 class=\"wp-block-heading\">11 Items to Check in a BMS System<\/h1>\n\n\n\n<h2 class=\"wp-block-heading\">Quick Review Checklist<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u2705 HVAC Control<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2705 Rotation Chiller<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2705 Rotation Pump<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2705 Scheduling Lighting<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2705 Water Monitoring<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2705 Electrical Metering<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2705 HVAC \u2013 Fire Interlock<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2705 Historical Trend<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2705 Remote Access<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2705 Audit Trail<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2705 Naming Convention Chu\u1ea9n<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If three or more items are missing, the system should be audited and re-evaluated.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h1 class=\"wp-block-heading\">Common Mistakes When Investing in BMS<\/h1>\n\n\n\n<h2 class=\"wp-block-heading\">No Sequence of Operation<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The system is running, but nobody knows the logic behind it.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">No Standard I\/O List<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">R\u1ea5t kh\u00f3 b\u1ea3o tr\u00ec v\u00e0 m\u1edf r\u1ed9ng.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Kh\u00f4ng Commissioning \u0110\u1ea7y \u0110\u1ee7<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The device is working, but its performance is low.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">No Audit Trail<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Difficult to determine:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Ai thay \u0111\u1ed5i<\/li>\n\n\n\n<li>Th\u1eddi \u0111i\u1ec3m thay \u0111\u1ed5i<\/li>\n\n\n\n<li>Parameters change<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Kh\u00f4ng C\u00f3 Mobile Access<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">FM has to go to the control room every time it needs to be checked<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h1 class=\"wp-block-heading\">When Should You Upgrade Your BMS?<\/h1>\n\n\n\n<p class=\"wp-block-paragraph\">You should consider upgrading when:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Building expansion<\/li>\n\n\n\n<li>Thay \u0111\u1ed5i c\u00f4ng n\u0103ng<\/li>\n\n\n\n<li>Increase the number of tenants<\/li>\n\n\n\n<li>T\u00edch h\u1ee3p ESG<\/li>\n\n\n\n<li>IoT integration<\/li>\n\n\n\n<li>Integrated multi-building dashboard<\/li>\n\n\n\n<li>BMS is no longer supported.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h1 class=\"wp-block-heading\">Conclude<\/h1>\n\n\n\n<p class=\"wp-block-paragraph\">BMS is not a dashboard screen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">BMS is a platform for controlling and automating the electromechanical systems of a building.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A properly designed BMS system will help:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Reduce operating costs.<\/li>\n\n\n\n<li>Increase system stability<\/li>\n\n\n\n<li>Enhance the user experience.<\/li>\n\n\n\n<li>Supporting Facility Managers in making better decisions.<\/li>\n\n\n\n<li>Laying the foundation for the future of IoT and Smart Building.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">What support does GEEC provide for the BMS project?<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Existing Marine BMS system<\/li>\n\n\n\n<li>Consulting services for Building Management System design.<\/li>\n\n\n\n<li>Integrated HVAC \u00b7 Electrical \u00b7 Plumbing \u00b7 Fire Protection<\/li>\n\n\n\n<li>IoT \u00b7 Dashboard \u00b7 Smart Building<\/li>\n\n\n\n<li>Commissioning &amp; Operational Training<\/li>\n\n\n\n<li>System maintenance and upgrades<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udcde <strong>Hotline:<\/strong> 079.861.9999<br>\ud83d\udce7 <strong>Email:<\/strong> info@geec.vn<br>\ud83c\udf10 <strong>Website:<\/strong> www.geec.vn<\/p>","protected":false},"excerpt":{"rendered":"<p>Trong nhi\u1ec1u d\u1ef1 \u00e1n hi\u1ec7n nay, c\u1ee5m t\u1eeb BMS (Building Management System) th\u01b0\u1eddng \u0111\u01b0\u1ee3c s\u1eed d\u1ee5ng nh\u01b0 m\u1ed9t gi\u1ea3i ph\u00e1p &#8220;qu\u1ea3n l\u00fd t\u1ea5t c\u1ea3&#8221;. Tuy nhi\u00ean tr\u00ean th\u1ef1c t\u1ebf, r\u1ea5t nhi\u1ec1u c\u00f4ng tr\u00ecnh \u0111\u00e3 \u0111\u1ea7u t\u01b0 h\u00e0ng t\u1ef7 \u0111\u1ed3ng cho BMS nh\u01b0ng sau b\u00e0n giao v\u1eabn ph\u1ea3i s\u1eed d\u1ee5ng th\u00eam nhi\u1ec1u ph\u1ea7n m\u1ec1m kh\u00e1c nhau [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1387,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"zakra_page_container_layout":"customizer","zakra_page_sidebar_layout":"customizer","zakra_remove_content_margin":false,"zakra_sidebar":"customizer","zakra_transparent_header":"0","zakra_logo":0,"zakra_main_header_style":"default","zakra_menu_item_color":"","zakra_menu_item_hover_color":"","zakra_menu_item_active_color":"","zakra_menu_active_style":"","zakra_page_header":false,"footnotes":""},"categories":[28],"tags":[33,29,34,35,30,38,37,36,32,31],"class_list":["post-1707","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-iot-thong-minh","tag-bms-hvac","tag-bms-la-gi","tag-bms-panasonic","tag-bms-toa-nha","tag-building-management-system","tag-facility-management","tag-giai-phap-bms","tag-he-thong-bms","tag-iot-dashboard","tag-smart-building"],"_links":{"self":[{"href":"https:\/\/geec.vn\/en\/wp-json\/wp\/v2\/posts\/1707","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/geec.vn\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/geec.vn\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/geec.vn\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/geec.vn\/en\/wp-json\/wp\/v2\/comments?post=1707"}],"version-history":[{"count":2,"href":"https:\/\/geec.vn\/en\/wp-json\/wp\/v2\/posts\/1707\/revisions"}],"predecessor-version":[{"id":1709,"href":"https:\/\/geec.vn\/en\/wp-json\/wp\/v2\/posts\/1707\/revisions\/1709"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/geec.vn\/en\/wp-json\/wp\/v2\/media\/1387"}],"wp:attachment":[{"href":"https:\/\/geec.vn\/en\/wp-json\/wp\/v2\/media?parent=1707"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/geec.vn\/en\/wp-json\/wp\/v2\/categories?post=1707"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/geec.vn\/en\/wp-json\/wp\/v2\/tags?post=1707"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}